BOS Beam Observation Systems Quote Form

 

                   FORMAL QUOTE              PRICES ONLY

 Standard Systems

  BOS-18, Beam Observation System, 18mm Diameter Imaging Area (Chamber: welded window,2.75" Conflat®)

  BOS-18-FO, Beam Observation System, 18mm Diameter Imaging Area (Fiberoptic window, 2.75" Conflat®)  

  BOS-18-IW, Beam Observation System, 18mm Diameter Imaging Area, Image Wedge, 90-Degree Imaging

  BOS-25, Beam Observation System, 25mm Diameter Imaging Area (welded window, 4.50" Conflat®)

  BOS-25-6, Beam Observation System, 25mm Diameter Imaging Area (welded window, 6.00" Conflat®)

  BOS-40, Beam Observation System, 40mm Diameter Imaging Area (Chamber: welded window,4.50" Conflat®)

  BOS-40-6, Beam Observation System, 40mm Diameter Imaging Area (welded window, 6.00" Conflat®)

  BOS-40-6-FO, Beam Observation System, 40mm Diameter Imaging Area (Fiberoptic window, 6.00" Conflat®)  

  BOS-40-IW, Beam Observation System, 40mm Diameter Imaging Area, Image Wedge, 90-Degree Imaging

  BOS-75, Beam Observation System, 75mm Diameter Imaging Area (welded window, 8.00" Conflat®)

  BOS-75-FO, Beam Observation System, 75mm Diameter Imaging Area (Fiberoptic Window, 8.00" Conflat®)

 

OPTIONS

  MCP

  Dual MCP, (OPT-01).

  Impedance matched MCPs, (Dual MCP option only).

  MCP Coating, (Input Side). Choose from CsI, CuI, MgF2, MgO, KBr, Cu, and Au

  Pitch (choose 3,6,10,12, or 32) Bias Angle (Choose 0,5,8,12,or 19 Deg.)

  Aspect Ratio (choose 60:1 or 80:1)

  MCP Front surface to Flange vacuum side surface distance(BOS-25-6-EXT and BOS-40-6-EXT        only) (mm)

 

 Phosphor Screen

 P-43 (15 micron) with Aluminum (500Å) overcoat standard

  Phosphor type, Please state desired phosphor type and conductive coating type if required

  Metal anode in place of phosphor screen, particle detection applications. (Reduces cost of base system. Usually specified with no viewport chamber option(see below)).

   Vacuum chamber viewport type

 Standard window is welded pyrex glass window.

Options included:

  Pyrex, Removeable.

  Quartz, Removeable.

  Fused Silica, Removeable.

  Sapphire, Removeable.

  Fiberoptic/phosphor screen window, removeable.

  No Viewport (Reduces cost of base system. Normally specified with metal anode for particle detection only).

  Feedthroughs

Standard feedthroughs are MHV, 5kV with feedthrough orientation out of EDGE of flange.

  SHV, 5kV.

  SHV-B, 7.5kV. (Phosphor screen only)

  50 Ohm BNC Feedthrough for metal anode connection.  Particle detection systems with metal anode configuration.

  Feedthrough orientation- Out of FACE of flange.

 

Imager/Detector Shield

MCP/Phosphor screen assembly has a shield assembly at front of imager/detector to shield MCP/phosphor potentials from incoming beam. This shield is normally grounded to vacuum chamber. 

  Floating shield. Attached to MCP front connection. Allows MCP front to be biased to a potential        other than ground.

 

Beam Attenuation Grids for prolonging MCP life

  Ion beams greater than 3.2 nA/mm2, 90% beam attenuation (1 grid)

  Ion beams greater than 31.8 nA/mm2, 99% beam attenuation (2 grids)

  Ion beams greater than 318.nA/mm2, 99.9% beam attenuation (3 grids)

  Electron Suppression Grid

  99% transmission grid for electron suppression.

  Camera Systems

Include camera, lens, mounting hardware and monochrome video monitor.

  BOS-OPT02/2622 (COHU 2622)

  BOS-OPT02/2722 (COHU 2722)

  BOS-OPT02/3710 (CIDTEC 3710D)

  Custom, customer specified

  Image Processing System 

  Video monitor, PCI bus Frame grabber, Image Processing Software 

  Power Supplies:

  Single MCP, 0-1kV

  Dual MCP, 0-2kV

  Phosphor Screen, 0-5kV

   